User Tools

Site Tools


zeiss_axiovert_200m

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
zeiss_axiovert_200m [2020/01/01 20:59]
bioimaging [Objectives]
zeiss_axiovert_200m [2020/01/14 17:42]
bioimaging [System Turn On Procedures]
Line 32: Line 32:
  
   * **Microscope**:​ Zeiss Axiovert 200   * **Microscope**:​ Zeiss Axiovert 200
-  * **Camera**: [[https://​labs.pbrc.edu/​cellbiology/​documents/​CoolSNAPHQ.pdf|Photometrics Coolsnap HQ CCD]]+  * **Monochrome ​Camera**: [[https://​labs.pbrc.edu/​cellbiology/​documents/​CoolSNAPHQ.pdf|Photometrics Coolsnap HQ CCD]] 
 +  * **Color Camera**: [[https://​www.leica-microsystems.com/​products/​microscope-cameras/​p/​leica-dfc450-c/​|Leica DFC450]]
  
 {{:​warning.png?​25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link. {{:​warning.png?​25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link.
Line 65: Line 66:
 ^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ^ (color) ​ 10 μm =  ^  Reference ​ ^ ^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ^ (color) ​ 10 μm =  ^  Reference ​ ^
 |  10x  |  EC Plan-Neofluar ​ |  Air  |  0.30  |  5.2  |  1.00  |  10 pixels ​ |  23.3 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420340-9901-000/​Objective-EC-Plan-Neofluar-10x-0.30-M27|420340-9901-000]] ​ | |  10x  |  EC Plan-Neofluar ​ |  Air  |  0.30  |  5.2  |  1.00  |  10 pixels ​ |  23.3 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420340-9901-000/​Objective-EC-Plan-Neofluar-10x-0.30-M27|420340-9901-000]] ​ |
-|  20x  |  ​[[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420650-9901-000|EC Plan-Neofluar]]  ​|  ​Dry  ​| ​ 0.50  |  2  |  0.48  |  21 pixels ​ |  46.7 pixels ​ | +|  20x  |  EC Plan-Neofluar ​ |  ​Air  ​| ​ 0.50  |  2  |  0.48  |  21 pixels ​ |  46.7 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420350-9900-000/Objective-EC-Plan-Neofluar-20x-0.50-M27|420350-9900-000]]  ​
-|  40x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440350-9903-000|EC Plan-NeoFluar]]  |  ​Dry  ​| ​ 0.75  |  0.71  |  0.24  |  41 pixels ​ |  93.7 pixels ​ | +|  ​40x  |  EC Plan-NeoFluar ​ |  Air  ​| ​ 0.75  |  0.71  |  0.24  |  41 pixels ​ |  93.7 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440350-9903-000/​Objective-EC-Plan-Neofluar-40x-0.75|440350-9903-000]]  | 
-|  63x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420782-9900-000|Plan-Apochromat]]  |  Oil  |  1.40  |  0.19  |  0.15  |  65 pixels ​ |  -  |+|  63x  |  Plan-Apochromat DIC  ​| ​ Oil  |  1.40  |  0.19  |  0.15  |  65 pixels ​ |  -  ​| ​ [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420782-9900-000/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-000]] ​ |
  
  
 **Upon request:** **Upon request:**
-^  Magnification ​ ^  Model  ^  ​Type  ​^ ​ NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ^ +^  Magnification ​ ^  Model  ^  ​Immersion ​ ​^ ​ NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ​^ ​ Reference ​ ^ 
-|  1.25x  |  ​[[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=422310-9900-000|EC Epiplan-Neofluar]]  ​|  ​Dry  ​| ​ 0.035  |  4  |  7.58  |  1.3 pixels ​ | +|  1.25x  |  EC Epiplan-Neofluar ​ |  ​Air  ​| ​ 0.035  |  4  |  7.58  |  1.3 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​422310-9900-000/​Objective-EC-Epiplan-Neofluar-1.25x-0.03-M27|422310-9900-000]] ​ | 
-|  5x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=571974962233f6&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420330-9901-000|EC Plan-NeoFluar]]  ​|  ​Dry  ​| ​ 0.16  |  18.5  |  2.00  |  5 pixels ​ | +|  5x  |  ​EC Plan-NeoFluar ​ |  ​Air  ​| ​ 0.16  |  18.5  |  2.00  |  5 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420330-9901-000/​Objective-EC-Plan-Neofluar-5x-0.16-M27|420330-9901-000]] ​ | 
-|  20x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440341-9904-000|EC Plan-Neofluar Ph 2]]  ​|  ​Dry  ​| ​ 0.50  |  2  |  0.48  |  21 pixels ​ | +|  20x  |  ​EC Plan-Neofluar Ph 2  |  ​Air  ​| ​ 0.50  |  2  |  0.48  |  21 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440341-9904-000/​Objective-EC-Plan-Neofluar-20x-0.5-Ph2|440341-9904-000]]  | 
-|  40x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440451-9903-000|Plan-Neofluar ​Ph3]]  |  Oil  |  1.30  |  0.20  |  0.24  |  41 pixels ​ | +|  40x  |  Plan-Neofluar Ph3  ​| ​ Oil  |  1.30  |  0.20  |  0.24  |  41 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440451-9903-000/​Objective-EC-Plan-Neofluar-40x-1.30-Oil-Ph3|440451-9903-000]]  | 
-|  63x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=571858182d6d9d&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420781-9910-000|Plan-Apochromat ​Ph3]]  |  Oil  |  1.4  |  0.19  |  0.15  |  65 pixels ​ |+|  63x  |  Plan-Apochromat Ph3  ​| ​ Oil  |  1.4  |  0.19  |  0.15  |  65 pixels ​ ​| ​ [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420781-9910-000/​Objective-Plan-Apochromat-63-1.4-Oil-Ph3-M27|420781-9910-000]] ​ |
  
 *** pixel sizes for binning = 1** *** pixel sizes for binning = 1**
 +
 +==== Cameras ====
 +^  Model  ^  Type  ^  Frame Size  ^  Pixel Size (µm)  ^
 +|  [[https://​labs.pbrc.edu/​cellbiology/​documents/​CoolSNAPHQ.pdf|Photometrics Coolsnap HQ]]  |  CCD  |  1392 x 1040  |  6.45 x 6.45  |
 +|  [[https://​www.leica-microsystems.com/​products/​microscope-cameras/​p/​leica-dfc450-c/​|Leica DFC450]] ​ |  color CCD  |  2560 × 1920  |  3.4 x 3.4  |
  
 ==== Stage ==== ==== Stage ====
Line 86: Line 92:
  
 ===== System Turn On Procedures ===== ===== System Turn On Procedures =====
-  * Turn the fluorescence ​light power source ​on.+  * Turn on the fluorescent ​light power source
 {{halide_710.jpg?​80|}} {{halide_710.jpg?​80|}}
-  * Turn on the Uniblitz shutter controller (on the back). +  * Turn on the Prior stage controller ​
-{{ax_uniblitz1.jpg?​100|}}{{ax_uniblitz2.jpg?​100|}} +
-  * Turn the Prior microscope ​stage controller ​on. +
 {{ax_prior_on.jpg?​100|}} {{ax_prior_on.jpg?​100|}}
-  * Wait 10s then turn the microscope ​on.+  * Turn on the microscope
 {{ax_mic_on.jpg?​100|}} {{ax_mic_on.jpg?​100|}}
-  * Turn the camera ​on.+  * Turn on the CCD camera
 {{ax_cam_on.jpg?​100|}} {{ax_cam_on.jpg?​100|}}
-  * Turn the computer ​on. +  * Turn on the computer 
-  * Login to the computer ​(Axiovert 200M user). +  * Log in to Windows ​(Bioimaging User
-  * Start the Metamorph software. +  * Start the Metamorph software 
-  * If you need temperature control, turn on the control box +  * If the software doesn'​t detect the camerapower cycle the camera ​and try again
-{{heating2.jpg?​100|}} +
-  * If you need CO2open the valve and turn on CO2 supply on the control box +
-{{co2.jpg?​100|}} +
 ===== Microscope Turn Off procedures ===== ===== Microscope Turn Off procedures =====
   * Turn off the computer.   * Turn off the computer.
Line 109: Line 109:
   * If you used any __immersion oil in the objectives, clean them up__.   * If you used any __immersion oil in the objectives, clean them up__.
   * Turn off the microscope stage controller.   * Turn off the microscope stage controller.
-  * Turn off the shutter controller. 
   * Turn off the microscope.   * Turn off the microscope.
   * If there'​s __another user__ for this microscope in the __next hour__ leave the mercury __lamp power source on, else turn it off__. ​   * If there'​s __another user__ for this microscope in the __next hour__ leave the mercury __lamp power source on, else turn it off__. ​
zeiss_axiovert_200m.txt · Last modified: 2024/02/12 22:50 by bioimaging