- | <img src="/facility/bioimaging/lib/exe/fetch.php?media=axiovert_200m_name.jpg"> | + | <img src="/facility/bioimaging/lib/exe/fetch.php?media=zeiss_axiovert_200m_name_new.png"> |
<table style="border:0px solid white;"> | <table style="border:0px solid white;"> | ||
<tr style="border:0px solid white;"> | <tr style="border:0px solid white;"> | ||
<td style="border:0px solid white;"> | <td style="border:0px solid white;"> | ||
- | <a href="/facility/bioimaging/lib/exe/fetch.php?media=zeiss_axiovert_200m_wiki.jpg"><img src="/facility/bioimaging/lib/exe/fetch.php?media=zeiss_axiovert_200m_wiki.jpg" width=300></a> | + | <a href="/facility/bioimaging/lib/exe/fetch.php?media=zeiss_axiovert_200m_wiki_new.png"><img src="/facility/bioimaging/lib/exe/fetch.php?media=zeiss_axiovert_200m_wiki_new.png" width=300></a> |
<td style="border:0px solid white;"> <p style="line-height:1.8"> | <td style="border:0px solid white;"> <p style="line-height:1.8"> | ||
- | <b>Location</b>: <a href="/facility/bioimaging/lib/exe/fetch.php?media=zeiss_axiovert_200m_map.jpg">Room P2-A-22</a> (<img src="/facility/bioimaging/lib/exe/fetch.php?media=telephone_icon.gif" width=15> 47217) <br> | + | <b>Location</b>: <a href="/facility/bioimaging/lib/exe/fetch.php?media=zeiss_axiovert_200m_map_new.png">Room P2-A-22</a> (<img src="/facility/bioimaging/lib/exe/fetch.php?media=phone_neg.png" width=15> 47217) <br> |
<b>Manufacturer</b>: <a href="http://www.zeiss.de/micro" target="_blank">Carl Zeiss MicroImaging</a><br> | <b>Manufacturer</b>: <a href="http://www.zeiss.de/micro" target="_blank">Carl Zeiss MicroImaging</a><br> | ||
<b>Model</b>: Axiovert 200M<br> | <b>Model</b>: Axiovert 200M<br> | ||
Line 13: | Line 13: | ||
<b>Year</b>: 2003 <br> | <b>Year</b>: 2003 <br> | ||
<b>SN</b>: ZCA522000494<br> | <b>SN</b>: ZCA522000494<br> | ||
+ |   <br> | ||
  <br> |   <br> | ||
  <br> |   <br> | ||
Line 20: | Line 21: | ||
<br> | <br> | ||
→ <a href="/facility/bioimaging/doku.php?id=zeiss_axiovert_200m_usage"><img src="/facility/bioimaging/lib/exe/fetch.php?media=chart_line.png"> Zeiss Axiovert 200M Usage Statistics</a> | → <a href="/facility/bioimaging/doku.php?id=zeiss_axiovert_200m_usage"><img src="/facility/bioimaging/lib/exe/fetch.php?media=chart_line.png"> Zeiss Axiovert 200M Usage Statistics</a> | ||
- | <br> | + | </p> |
- | → <a href="/facility/bioimaging/doku.php?id=zeiss_axiovert_200m_repair"><img src="/facility/bioimaging/lib/exe/fetch.php?media=repair-icon.gif" width=16> Zeiss Axiovert 200M Repair History</a> | + | |
- | </p> | + | |
</td> | </td> | ||
</tr> | </tr> | ||
Line 30: | Line 29: | ||
===== Microscope overview ===== | ===== Microscope overview ===== | ||
- | The Zeiss Axiovert 200M is a fully motorized inverted //widefield fluorescence microscope// ideal for live-cell imaging applications. It is equipped with a small stage incubator for temperature control and CO2 supply. Using the Metamorph software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled CCD camera (Photometrics Coolsnap HQ CCD) allows you to capture weak fluorescent signals and minimize photobleaching/photodamage in light sensitive samples. You can also perform Z-stack acquisition and use our [[http://micro.magnet.fsu.edu/primer/digitalimaging/deconvolution/deconvolutionhome.html|deconvolution]] server [[brainstorm|Brainstorm]] to significantly improve image resolution even in thick samples. If you are performing long time-lapse experiments in live samples (aqueous media) and need hardware focus control, check the [[zeiss_cell_observer|Zeiss Cell Observer]] with Definite Focus. If don't want to use deconvolution, check out one of the confocal systems such as the point scanners [[zeiss_lsm_710|Zeiss LSM 710]] and [[zeiss_lsm_880|Zeiss LSM 880]] or the spinning disks [[3i_marianas_sdc|3i Marianas SDC]] and [[zeiss_cell_observer_sd|Zeiss Cell Observer SD]]. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]]. If you have FISH or other fixed fluorescence slides try the [[leica_dm5000b|Leica DM5000B]] instead. | + | The Zeiss Axiovert 200M is a fully motorized inverted //widefield fluorescence microscope// ideal for live-cell imaging applications. It is equipped with a small stage incubator for temperature control and CO2 supply. Using the Metamorph software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled CCD camera (Photometrics Coolsnap HQ CCD) allows you to capture weak fluorescent signals and minimize photobleaching/photodamage in light sensitive samples. You can also perform Z-stack acquisition and use [[https://huygens.i3s.up.pt/login.php|PPBI Huygens RM]] [[http://micro.magnet.fsu.edu/primer/digitalimaging/deconvolution/deconvolutionhome.html|deconvolution]] server to significantly improve image resolution even in thick samples. If you are performing long time-lapse experiments in live samples (aqueous media) and need hardware focus control, check the [[zeiss_cell_observer|Zeiss Cell Observer]] with Definite Focus. If don't want to use deconvolution, check out one of the confocal systems such as the point scanners [[zeiss_lsm_710|Zeiss LSM 710]] and [[zeiss_lsm_880|Zeiss LSM 880]] or the spinning disks [[3i_marianas_sdc|3i Marianas SDC]] and [[zeiss_cell_observer_sd|Zeiss Cell Observer SD]]. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]]. If you have FISH or other fixed fluorescence slides try the [[leica_dm5000b|Leica DM5000B]] instead. |
* **Microscope**: Zeiss Axiovert 200 | * **Microscope**: Zeiss Axiovert 200 | ||
- | * **Camera**: Photometrics Coolsnap HQ CCD | + | * **Monochrome Camera**: [[https://labs.pbrc.edu/cellbiology/documents/CoolSNAPHQ.pdf|Photometrics Coolsnap HQ CCD]] |
+ | * **Color Camera**: [[https://www.leica-microsystems.com/products/microscope-cameras/p/leica-dfc450-c/|Leica DFC450]] | ||
- | {{warning.jpg?20|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link. | + | {{:warning.png?25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link. |
===== Booking Rules ===== | ===== Booking Rules ===== | ||
Line 64: | Line 64: | ||
==== Objectives ==== | ==== Objectives ==== | ||
- | ^ Magnification ^ Model ^ Type ^ NA ^ WD (mm) ^ pixel size* (μm) ^ 10 μm = ^ (color camera) 10 μm = ^ | + | ^ Magnification ^ Model ^ Immersion ^ NA ^ WD (mm) ^ pixel size* (μm) ^ 10 μm = ^ (color) 10 μm = ^ Reference ^ |
- | | 10x | [[https://www.micro-shop.zeiss.com/?s=3407786617d462&l=en&p=uk&f=o&a=v&m=s&id=420340-9901-000|EC Plan-Neofluar]] | Dry | 0.30 | 5.2 | 1.00 | 10 pixels | 23.3 pixels | | + | | 10x | EC Plan-Neofluar | Air | 0.30 | 5.2 | 1.00 | 10 pixels | 23.3 pixels | [[https://www.micro-shop.zeiss.com/en/de/shop/objectives/420340-9901-000/Objective-EC-Plan-Neofluar-10x-0.30-M27|420340-9901-000]] | |
- | | 20x | [[https://www.micro-shop.zeiss.com/?s=3407786617d462&l=en&p=uk&f=o&a=v&m=s&id=420650-9901-000|EC Plan-Neofluar]] | Dry | 0.50 | 2 | 0.48 | 21 pixels | 46.7 pixels | | + | | 20x | EC Plan-Neofluar | Air | 0.50 | 2 | 0.48 | 21 pixels | 46.7 pixels | [[https://www.micro-shop.zeiss.com/en/de/shop/objectives/420350-9900-000/Objective-EC-Plan-Neofluar-20x-0.50-M27|420350-9900-000]] | |
- | | 40x | [[https://www.micro-shop.zeiss.com/?s=3407786617d462&l=en&p=uk&f=o&a=v&m=s&id=440350-9903-000|EC Plan-NeoFluar]] | Dry | 0.75 | 0.71 | 0.24 | 41 pixels | 93.7 pixels | | + | | 40x | EC Plan-NeoFluar | Air | 0.75 | 0.71 | 0.24 | 41 pixels | 93.7 pixels | [[https://www.micro-shop.zeiss.com/en/de/shop/objectives/440350-9903-000/Objective-EC-Plan-Neofluar-40x-0.75|440350-9903-000]] | |
- | | 63x | [[https://www.micro-shop.zeiss.com/?s=3407786617d462&l=en&p=uk&f=o&a=v&m=s&id=420782-9900-000|Plan-Apochromat]] | Oil | 1.40 | 0.19 | 0.15 | 65 pixels | - | | + | | 63x | Plan-Apochromat DIC | Oil | 1.40 | 0.19 | 0.15 | 65 pixels | - | [[https://www.micro-shop.zeiss.com/en/de/shop/objectives/420782-9900-000/Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-000]] | |
**Upon request:** | **Upon request:** | ||
- | ^ Magnification ^ Model ^ Type ^ NA ^ WD (mm) ^ pixel size* (μm) ^ 10 μm = ^ | + | ^ Magnification ^ Model ^ Immersion ^ NA ^ WD (mm) ^ pixel size* (μm) ^ 10 μm = ^ Reference ^ |
- | | 1.25x | [[https://www.micro-shop.zeiss.com/?s=3407786617d462&l=en&p=uk&f=o&a=v&m=s&id=422310-9900-000|EC Epiplan-Neofluar]] | Dry | 0.035 | 4 | 7.58 | 1.3 pixels | | + | | 1.25x | EC Epiplan-Neofluar | Air | 0.035 | 4 | 7.58 | 1.3 pixels | [[https://www.micro-shop.zeiss.com/en/de/shop/objectives/422310-9900-000/Objective-EC-Epiplan-Neofluar-1.25x-0.03-M27|422310-9900-000]] | |
- | | 5x | [[https://www.micro-shop.zeiss.com/?s=571974962233f6&l=en&p=uk&f=o&a=v&m=s&id=420330-9901-000|EC Plan-NeoFluar]] | Dry | 0.16 | 18.5 | 2.00 | 5 pixels | | + | | 5x | EC Plan-NeoFluar | Air | 0.16 | 18.5 | 2.00 | 5 pixels | [[https://www.micro-shop.zeiss.com/en/de/shop/objectives/420330-9901-000/Objective-EC-Plan-Neofluar-5x-0.16-M27|420330-9901-000]] | |
- | | 20x | [[https://www.micro-shop.zeiss.com/?s=3407786617d462&l=en&p=uk&f=o&a=v&m=s&id=440341-9904-000|EC Plan-Neofluar Ph 2]] | Dry | 0.50 | 2 | 0.48 | 21 pixels | | + | | 20x | EC Plan-Neofluar Ph 2 | Air | 0.50 | 2 | 0.48 | 21 pixels | [[https://www.micro-shop.zeiss.com/en/de/shop/objectives/440341-9904-000/Objective-EC-Plan-Neofluar-20x-0.5-Ph2|440341-9904-000]] | |
- | | 40x | [[https://www.micro-shop.zeiss.com/?s=3407786617d462&l=en&p=uk&f=o&a=v&m=s&id=440451-9903-000|Plan-Neofluar Ph3]] | Oil | 1.30 | 0.20 | 0.24 | 41 pixels | | + | | 40x | Plan-Neofluar Ph3 | Oil | 1.30 | 0.20 | 0.24 | 41 pixels | [[https://www.micro-shop.zeiss.com/en/de/shop/objectives/440451-9903-000/Objective-EC-Plan-Neofluar-40x-1.30-Oil-Ph3|440451-9903-000]] | |
- | | 63x | [[https://www.micro-shop.zeiss.com/?s=571858182d6d9d&l=en&p=uk&f=o&a=v&m=s&id=420781-9910-000|Plan-Apochromat Ph3]] | Oil | 1.4 | 0.19 | 0.15 | 65 pixels | | + | | 63x | Plan-Apochromat Ph3 | Oil | 1.4 | 0.19 | 0.15 | 65 pixels | [[https://www.micro-shop.zeiss.com/en/de/shop/objectives/420781-9910-000/Objective-Plan-Apochromat-63-1.4-Oil-Ph3-M27|420781-9910-000]] | |