User Tools

Site Tools


zeiss_axiovert_200m

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
zeiss_axiovert_200m [2016/04/06 00:45]
bioimaging
zeiss_axiovert_200m [2016/06/29 13:11]
bioimaging [Microscope overview]
Line 15: Line 15:
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
-&rarr; <a href="​https://​imm.medicina.ulisboa.pt/​intranet/​booking/​month.php?​user=AXIOVERT&​rid=3"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss Axiovert 200M Booking</​a>​+&rarr; <a href="​https://​imm.medicina.ulisboa.pt/​intranet/​booking/​3"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss Axiovert 200M Booking</​a>​
  <​br> ​  <​br> ​
 &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert200m_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss Axiovert 200M Quality Control</​a>​ &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert200m_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss Axiovert 200M Quality Control</​a>​
Line 30: Line 30:
 ===== Microscope overview ===== ===== Microscope overview =====
  
-The Zeiss Axiovert 200M is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. It is equipped with a small stage incubator for temperature control and CO2 supply. Using the Metamorph software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled CCD camera (Roper Scientific Coolsnap HQ CCD) allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. You can also perform Z-stack acquisition and use our [[http://​micro.magnet.fsu.edu/​primer/​digitalimaging/​deconvolution/​deconvolutionhome.html|deconvolution]] server [[brainstorm|Brainstorm]] to significantly improve image resolution even in thick samples. If you are performing long time-lapse experiments in live samples (aqueous media) and need hardware focus control, check the [[zeiss_cell_observer_wf|Zeiss ​Cell Observer ​WF]] with Definite Focus. If don't want to use deconvolution,​ check out one of the confocal systems such as the [[zeiss_lsm_710|Zeiss LSM 710]], [[zeiss_lsm_880|Zeiss LSM 880]] or the [[3i_marianas_sdc|3i Marianas SDC]] spinning disk. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]]. If you have FISH or other fixed fluorescence slides try the [[leica_dm5000b|Leica DM5000B]] instead.+The Zeiss Axiovert 200M is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. It is equipped with a small stage incubator for temperature control and CO2 supply. Using the Metamorph software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled CCD camera (Roper Scientific Coolsnap HQ CCD) allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. You can also perform Z-stack acquisition and use our [[http://​micro.magnet.fsu.edu/​primer/​digitalimaging/​deconvolution/​deconvolutionhome.html|deconvolution]] server [[brainstorm|Brainstorm]] to significantly improve image resolution even in thick samples. If you are performing long time-lapse experiments in live samples (aqueous media) and need hardware focus control, check the [[zeiss_axio_observer|Zeiss ​Axio Observer]] with Definite Focus. If don't want to use deconvolution,​ check out one of the confocal systems such as the [[zeiss_lsm_710|Zeiss LSM 710]], [[zeiss_lsm_880|Zeiss LSM 880]] or the [[3i_marianas_sdc|3i Marianas SDC]] spinning disk. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]]. If you have FISH or other fixed fluorescence slides try the [[leica_dm5000b|Leica DM5000B]] instead.
  
 ===== Booking Rules ===== ===== Booking Rules =====
Line 64: Line 64:
 ^  Magnification ​ ^  Model  ^  Type  ^  NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ^ (color camera) ​ 10 μm =  ^ ^  Magnification ​ ^  Model  ^  Type  ^  NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ^ (color camera) ​ 10 μm =  ^
 |  10x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420340-9901-000|EC Plan-Neofluar]] ​ |  Dry  |  0.30  |  5.2  |  1.00  |  10 pixels ​ |  23.3 pixels ​ | |  10x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420340-9901-000|EC Plan-Neofluar]] ​ |  Dry  |  0.30  |  5.2  |  1.00  |  10 pixels ​ |  23.3 pixels ​ |
-|  20x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440341-9904-000|EC Plan-Neofluar Ph 2]]  |  Dry  |  0.50  |  2  |  0.48  |  21 pixels ​ |  46.7 pixels ​ | 
 |  20x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420650-9901-000|EC Plan-Neofluar]] ​ |  Dry  |  0.50  |  2  |  0.48  |  21 pixels ​ |  46.7 pixels ​ | |  20x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420650-9901-000|EC Plan-Neofluar]] ​ |  Dry  |  0.50  |  2  |  0.48  |  21 pixels ​ |  46.7 pixels ​ |
 |  40x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440350-9903-000|EC Plan-NeoFluar]] ​ |  Dry  |  0.75  |  0.71  |  0.24  |  41 pixels ​ |  93.7 pixels ​ | |  40x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440350-9903-000|EC Plan-NeoFluar]] ​ |  Dry  |  0.75  |  0.71  |  0.24  |  41 pixels ​ |  93.7 pixels ​ |
 |  63x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420782-9900-000|Plan-Apochromat]] ​ |  Oil  |  1.40  |  0.19  |  0.15  |  65 pixels ​ |  -  | |  63x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420782-9900-000|Plan-Apochromat]] ​ |  Oil  |  1.40  |  0.19  |  0.15  |  65 pixels ​ |  -  |
-|  100x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440782-9902-000|Plan-Apochromat]] ​ |  Oil  |  1.40  |  0.17  |  0.10  |  102 pixels ​ |  -  |+
  
 **Upon request:** **Upon request:**
Line 74: Line 73:
 |  1.25x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=422310-9900-000|EC Epiplan-Neofluar]] ​ |  Dry  |  0.035  |  4  |  7.58  |  1.3 pixels ​ | |  1.25x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=422310-9900-000|EC Epiplan-Neofluar]] ​ |  Dry  |  0.035  |  4  |  7.58  |  1.3 pixels ​ |
 |  5x  |  [[https://​www.micro-shop.zeiss.com/?​s=571974962233f6&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420330-9901-000|EC Plan-NeoFluar]] ​ |  Dry  |  0.16  |  18.5  |  2.00  |  5 pixels ​ | |  5x  |  [[https://​www.micro-shop.zeiss.com/?​s=571974962233f6&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420330-9901-000|EC Plan-NeoFluar]] ​ |  Dry  |  0.16  |  18.5  |  2.00  |  5 pixels ​ |
-|  ​25x  ​| ​ [[https://​www.micro-shop.zeiss.com/?​s=129353259d52f12&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420852-9972-000|LCI Plan-NeoFluar]]  |  ​Oil/​Glyc/​W ​ ​| ​ 0. ​|  ​0.21  ​| ​ 0.40  ​|  ​25 pixels ​ | +|  ​20x  ​| ​ [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440341-9904-000|EC Plan-Neofluar Ph 2]]  |  ​Dry  ​| ​ 0.50  ​|  ​ ​| ​ 0.48  ​|  ​21 pixels ​ | 
-|  40x  |  [[https://​www.micro-shop.zeiss.com/?​s=129353259d52f12&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420660-9970-000|Plan-Apochromat]]  |  ​Dry  ​|  ​0.95  ​| ​ 0.25  ​| ​ 0.25  ​|  ​40 pixels ​ | +|  40x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440451-9903-000|Plan-Neofluar Ph3]]  |  ​Oil  ​|  ​1.30  ​| ​ 0.20  ​| ​ 0.24  ​|  ​41 pixels ​ | 
-|  63x (Ph 3)  ​| ​ [[https://​www.micro-shop.zeiss.com/?​s=571858182d6d9d&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420781-9910-000|Plan-Apochromat]] ​ |  Oil  |  1.4  |  0.19  |  0.15  |  65 pixels ​ |+|  63x  |  [[https://​www.micro-shop.zeiss.com/?​s=571858182d6d9d&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420781-9910-000|Plan-Apochromat ​Ph3]]  |  Oil  |  1.4  |  0.19  |  0.15  |  65 pixels ​ | 
 +|  100x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440782-9902-000|Plan-Apochromat]] ​ |  Oil  |  1.40  |  0.17  |  0.10  |  102 pixels ​ |
  
 *** pixel sizes for binning = 1** *** pixel sizes for binning = 1**
Line 89: Line 89:
 {{halide_710.jpg?​80|}} {{halide_710.jpg?​80|}}
   * Turn on the Uniblitz shutter controller (on the back).   * Turn on the Uniblitz shutter controller (on the back).
-{{ax_uniblitz1.jpg?​100|}}{{:​bioimaging:​ax_uniblitz2.jpg?​100|}}+{{ax_uniblitz1.jpg?​100|}}{{ax_uniblitz2.jpg?​100|}}
   * Turn the Prior microscope stage controller on.    * Turn the Prior microscope stage controller on. 
 {{ax_prior_on.jpg?​100|}} {{ax_prior_on.jpg?​100|}}
zeiss_axiovert_200m.txt · Last modified: 2024/02/12 22:50 by bioimaging