User Tools

Site Tools


zeiss_axiovert_200m

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
zeiss_axiovert_200m [2016/04/06 00:41]
bioimaging
zeiss_axiovert_200m [2016/06/08 17:38]
bioimaging [Objectives]
Line 15: Line 15:
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
-&rarr; <a href="​https://​imm.medicina.ulisboa.pt/​intranet/​booking/​month.php?​user=AXIOVERT&​rid=3"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss Axiovert 200M Booking</​a>​+&rarr; <a href="​https://​imm.medicina.ulisboa.pt/​intranet/​booking/​3"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss Axiovert 200M Booking</​a>​
  <​br> ​  <​br> ​
 &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert200m_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss Axiovert 200M Quality Control</​a>​ &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert200m_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss Axiovert 200M Quality Control</​a>​
Line 30: Line 30:
 ===== Microscope overview ===== ===== Microscope overview =====
  
-The Zeiss Axiovert 200M is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. It is equipped with a small stage incubator for temperature control and CO2 supply. Using the Metamorph software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled CCD camera (Roper Scientific Coolsnap HQ CCD) allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. You can also perform Z-stack acquisition and use our [[http://​micro.magnet.fsu.edu/​primer/​digitalimaging/​deconvolution/​deconvolutionhome.html|deconvolution]] server [[brainstorm|Brainstorm]] to significantly improve image resolution even in thick samples. If you are performing long time-lapse experiments in live samples (aqueous media) and need hardware focus control, check the [[zeiss_cell_observer_wf|Zeiss Cell Observer WF]] with Definite Focus. If don't want to use deconvolution,​ check out one of the confocal systems such as the [[zeiss_lsm_710|Zeiss LSM 710]], [[zeiss_lsm_880|Zeiss LSM 880]] or the [[3i_marianas_sdc|3i Marianas SDC]] spinning disk. If your personal computer cannot handle all the data you collected, check out the [[bioimaging:​bigguy|Big Guy]]. If you have FISH or other fixed fluorescence slides try the [[bioimaging:leica_dm5000b|Leica DM5000B]] instead. +The Zeiss Axiovert 200M is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. It is equipped with a small stage incubator for temperature control and CO2 supply. Using the Metamorph software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled CCD camera (Roper Scientific Coolsnap HQ CCD) allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. You can also perform Z-stack acquisition and use our [[http://​micro.magnet.fsu.edu/​primer/​digitalimaging/​deconvolution/​deconvolutionhome.html|deconvolution]] server [[brainstorm|Brainstorm]] to significantly improve image resolution even in thick samples. If you are performing long time-lapse experiments in live samples (aqueous media) and need hardware focus control, check the [[zeiss_cell_observer_wf|Zeiss Cell Observer WF]] with Definite Focus. If don't want to use deconvolution,​ check out one of the confocal systems such as the [[zeiss_lsm_710|Zeiss LSM 710]], [[zeiss_lsm_880|Zeiss LSM 880]] or the [[3i_marianas_sdc|3i Marianas SDC]] spinning disk. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]]. If you have FISH or other fixed fluorescence slides try the [[leica_dm5000b|Leica DM5000B]] instead.
- +
-{{:​bioimaging:​info.gif?​|}} **If you are not going to use fluorescence please write '​TL'​ in the Event Field name**+
  
 ===== Booking Rules ===== ===== Booking Rules =====
 The Axiovert 200M booking is divided in three daily slots: The Axiovert 200M booking is divided in three daily slots:
-|9:00 to 13:00|13:00 to 17:00|17:00 to 21:00|+ 9:00 to 13:00   13:00 to 17:00   17:00 to 21:00  |
  
   - A **user** can book at maximum **2 sessions per week**   - A **user** can book at maximum **2 sessions per week**
Line 66: Line 64:
 ^  Magnification ​ ^  Model  ^  Type  ^  NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ^ (color camera) ​ 10 μm =  ^ ^  Magnification ​ ^  Model  ^  Type  ^  NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ^ (color camera) ​ 10 μm =  ^
 |  10x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420340-9901-000|EC Plan-Neofluar]] ​ |  Dry  |  0.30  |  5.2  |  1.00  |  10 pixels ​ |  23.3 pixels ​ | |  10x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420340-9901-000|EC Plan-Neofluar]] ​ |  Dry  |  0.30  |  5.2  |  1.00  |  10 pixels ​ |  23.3 pixels ​ |
-|  20x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440341-9904-000|EC Plan-Neofluar Ph 2]]  |  Dry  |  0.50  |  2  |  0.48  |  21 pixels ​ |  46.7 pixels ​ | 
 |  20x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420650-9901-000|EC Plan-Neofluar]] ​ |  Dry  |  0.50  |  2  |  0.48  |  21 pixels ​ |  46.7 pixels ​ | |  20x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420650-9901-000|EC Plan-Neofluar]] ​ |  Dry  |  0.50  |  2  |  0.48  |  21 pixels ​ |  46.7 pixels ​ |
 |  40x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440350-9903-000|EC Plan-NeoFluar]] ​ |  Dry  |  0.75  |  0.71  |  0.24  |  41 pixels ​ |  93.7 pixels ​ | |  40x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440350-9903-000|EC Plan-NeoFluar]] ​ |  Dry  |  0.75  |  0.71  |  0.24  |  41 pixels ​ |  93.7 pixels ​ |
 |  63x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420782-9900-000|Plan-Apochromat]] ​ |  Oil  |  1.40  |  0.19  |  0.15  |  65 pixels ​ |  -  | |  63x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420782-9900-000|Plan-Apochromat]] ​ |  Oil  |  1.40  |  0.19  |  0.15  |  65 pixels ​ |  -  |
-|  100x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440782-9902-000|Plan-Apochromat]] ​ |  Oil  |  1.40  |  0.17  |  0.10  |  102 pixels ​ |  -  |+
  
 **Upon request:** **Upon request:**
Line 76: Line 73:
 |  1.25x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=422310-9900-000|EC Epiplan-Neofluar]] ​ |  Dry  |  0.035  |  4  |  7.58  |  1.3 pixels ​ | |  1.25x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=422310-9900-000|EC Epiplan-Neofluar]] ​ |  Dry  |  0.035  |  4  |  7.58  |  1.3 pixels ​ |
 |  5x  |  [[https://​www.micro-shop.zeiss.com/?​s=571974962233f6&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420330-9901-000|EC Plan-NeoFluar]] ​ |  Dry  |  0.16  |  18.5  |  2.00  |  5 pixels ​ | |  5x  |  [[https://​www.micro-shop.zeiss.com/?​s=571974962233f6&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420330-9901-000|EC Plan-NeoFluar]] ​ |  Dry  |  0.16  |  18.5  |  2.00  |  5 pixels ​ |
-|  ​25x  ​| ​ [[https://​www.micro-shop.zeiss.com/?​s=129353259d52f12&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420852-9972-000|LCI Plan-NeoFluar]]  |  ​Oil/​Glyc/​W ​ ​| ​ 0. ​|  ​0.21  ​| ​ 0.40  ​|  ​25 pixels ​ | +|  ​20x  ​| ​ [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440341-9904-000|EC Plan-Neofluar Ph 2]]  |  ​Dry  ​| ​ 0.50  ​|  ​ ​| ​ 0.48  ​|  ​21 pixels ​ | 
-|  40x  |  [[https://​www.micro-shop.zeiss.com/?​s=129353259d52f12&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420660-9970-000|Plan-Apochromat]]  |  ​Dry  ​|  ​0.95  ​| ​ 0.25  ​| ​ 0.25  ​|  ​40 pixels ​ | +|  40x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440451-9903-000|Plan-Neofluar Ph3]]  |  ​Oil  ​|  ​1.30  ​| ​ 0.20  ​| ​ 0.24  ​|  ​41 pixels ​ | 
-|  63x (Ph 3)  ​| ​ [[https://​www.micro-shop.zeiss.com/?​s=571858182d6d9d&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420781-9910-000|Plan-Apochromat]] ​ |  Oil  |  1.4  |  0.19  |  0.15  |  65 pixels ​ |+|  63x  |  [[https://​www.micro-shop.zeiss.com/?​s=571858182d6d9d&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420781-9910-000|Plan-Apochromat ​Ph3]]  |  Oil  |  1.4  |  0.19  |  0.15  |  65 pixels ​ | 
 +|  100x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440782-9902-000|Plan-Apochromat]] ​ |  Oil  |  1.40  |  0.17  |  0.10  |  102 pixels ​ |
  
 *** pixel sizes for binning = 1** *** pixel sizes for binning = 1**
Line 89: Line 87:
 ===== System Turn On Procedures ===== ===== System Turn On Procedures =====
   * Turn the fluorescence light power source on.   * Turn the fluorescence light power source on.
-{{:​bioimaging:​halide_710.jpg?​80|}}+{{halide_710.jpg?​80|}}
   * Turn on the Uniblitz shutter controller (on the back).   * Turn on the Uniblitz shutter controller (on the back).
-{{:​bioimaging:​ax_uniblitz1.jpg?​100|}}{{:​bioimaging:​ax_uniblitz2.jpg?​100|}}+{{ax_uniblitz1.jpg?​100|}}{{ax_uniblitz2.jpg?​100|}}
   * Turn the Prior microscope stage controller on.    * Turn the Prior microscope stage controller on. 
-{{:​bioimaging:​ax_prior_on.jpg?​100|}}+{{ax_prior_on.jpg?​100|}}
   * Wait 10s then turn the microscope on.   * Wait 10s then turn the microscope on.
-{{:​bioimaging:​ax_mic_on.jpg?​100|}}+{{ax_mic_on.jpg?​100|}}
   * Turn the camera on.   * Turn the camera on.
-{{:​bioimaging:​ax_cam_on.jpg?​100|}}+{{ax_cam_on.jpg?​100|}}
   * Turn the computer on.   * Turn the computer on.
   * Login to the computer (each group has it's own area and login).   * Login to the computer (each group has it's own area and login).
   * Start the Metamorph software.   * Start the Metamorph software.
   * If you need temperature control, turn on the control box   * If you need temperature control, turn on the control box
-{{:​bioimaging:​heating2.jpg?​100|}}+{{heating2.jpg?​100|}}
   * If you need CO2, open the valve and turn on CO2 supply on the control box   * If you need CO2, open the valve and turn on CO2 supply on the control box
-{{:​bioimaging:​co2.jpg?​100|}}+{{co2.jpg?​100|}}
  
 ===== Microscope Turn Off procedures ===== ===== Microscope Turn Off procedures =====
zeiss_axiovert_200m.txt · Last modified: 2024/02/12 22:50 by bioimaging