Next revision Both sides next revision
zeiss_axiovert_200m [2016/04/06 00:25]
bioimaging created
zeiss_axiovert_200m [2020/01/14 17:42]
bioimaging [System Turn On Procedures]
Line 1: Line 1:
 <​html>​ <​html>​
-<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_name.jpg">+<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_name_new.png">
 <table style="​border:​0px solid white;">​ <table style="​border:​0px solid white;">​
 <tr style="​border:​0px solid white;">​ <tr style="​border:​0px solid white;">​
 <td style="​border:​0px solid white;">​ <td style="​border:​0px solid white;">​
-<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_cell_observer_wf_wiki.jpg"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_cell_observer_wf_wiki.jpg" width=300></​a>​+<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_wiki_new.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_wiki_new.png" width=300></​a>​
 <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​ <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​
-<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_cell_observer_wf_map.jpg">​Room ​P3-A-10</a> (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=telephone_icon.gif" width=15> ​47311) <​br> ​+<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_map_new.png">​Room ​P2-A-22</a> (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png" width=15> ​47217) <​br> ​
 <​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​Carl Zeiss MicroImaging</​a><​br>​ <​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​Carl Zeiss MicroImaging</​a><​br>​
-<​b>​Model</​b>: ​Cell Observer<​br>​ +<​b>​Model</​b>: ​Axiovert 200M<​br>​ 
-<​b>​Software</​b>: ​ZEN 2 (blue edition)<​br>​ +<​b>​Nickname</​b>:​ "​Axiovert"​<​br>​ 
-<​b>​Year</​b>: ​2015 <​br>​ +<​b>​Software</​b>: ​Metamorph 7.7.9.0<​br>​ 
-<​b>​SN</​b>: ​1026052056<br>+<​b>​Year</​b>: ​2003 <​br>​ 
 +<​b>​SN</​b>: ​ZCA522000494<br>
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
-&nbsp <​br>​ +&rarr; <a href="​https://​imm.medicina.ulisboa.pt/​intranet/​booking/​3"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss Axiovert 200M Booking</​a>​
-&rarr; <a href="​https://​imm.medicina.ulisboa.pt/​intranet/​booking/​month.php?​user=ZEISSCELL1&​rid=125"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss Cell Observer WF Booking</​a>​+
  <​br> ​  <​br> ​
-&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_cell_observer_wf_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss Cell Observer WF Quality Control</​a>​+&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert200m_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss Axiovert 200M Quality Control</​a>​
  <​br>​  <​br>​
-&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_cell_observer_wf_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ Zeiss Cell Observer WF Usage Statistics</​a>​ +&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert_200m_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ Zeiss Axiovert 200M Usage Statistics</​a>​ 
- </​p>​+</p>
 </td> </td>
 </tr> </tr>
Line 27: Line 27:
 </​html>​ </​html>​
  
 +===== Microscope overview =====
 +
 +The Zeiss Axiovert 200M is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. It is equipped with a small stage incubator for temperature control and CO2 supply. Using the Metamorph software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled CCD camera (Photometrics Coolsnap HQ CCD) allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. You can also perform Z-stack acquisition and use [[https://​huygens.i3s.up.pt/​login.php|PPBI Huygens RM]] [[http://​micro.magnet.fsu.edu/​primer/​digitalimaging/​deconvolution/​deconvolutionhome.html|deconvolution]] server to significantly improve image resolution even in thick samples. If you are performing long time-lapse experiments in live samples (aqueous media) and need hardware focus control, check the [[zeiss_cell_observer|Zeiss Cell Observer]] with Definite Focus. If don't want to use deconvolution,​ check out one of the confocal systems such as the point scanners [[zeiss_lsm_710|Zeiss LSM 710]] and [[zeiss_lsm_880|Zeiss LSM 880]] or the spinning disks [[3i_marianas_sdc|3i Marianas SDC]] and [[zeiss_cell_observer_sd|Zeiss Cell Observer SD]]. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]]. If you have FISH or other fixed fluorescence slides try the [[leica_dm5000b|Leica DM5000B]] instead.
 +
 +  * **Microscope**:​ Zeiss Axiovert 200
 +  * **Monochrome Camera**: [[https://​labs.pbrc.edu/​cellbiology/​documents/​CoolSNAPHQ.pdf|Photometrics Coolsnap HQ CCD]]
 +  * **Color Camera**: [[https://​www.leica-microsystems.com/​products/​microscope-cameras/​p/​leica-dfc450-c/​|Leica DFC450]]
 +
 +{{:​warning.png?​25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link.
 +
 +===== Booking Rules =====
 +The Axiovert 200M booking is divided in three daily slots:
 +|  9:00 to 13:00  |  13:00 to 17:00  |  17:00 to 21:00  |
 +
 +  - A **user** can book at maximum **2 sessions per week**
 +  - Each **session must fit inside one of the three daily slots** (i.e. a session booked from 11:00 to 14:00 counts as 2 sessions)
 +  - The above rules do not apply for **weekends** and for work days **before 9:00** and **after 21:00**
 +  - The above rules do not apply for sessions booked on the very same day or **24 hours ahead**
 +  - Exceptions to these rules require **approval from [[joserino@medicina.ulisboa.pt|José Rino]]**.
 +
 +===== System components =====
 +
 +==== Filtersets ====
 +
 +^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Emission ​ ^
 +|  1  |  Blue  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488001-9901-000&​o=|FS01]] ​ |  359-371 nm  |  > 397 nm  |
 +|  2  |  Green BP  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488010-9901-000&​o=|FS10]] ​ |  450-490 nm  |  515-565 nm  |
 +|  3  |  Red  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488020-9901-000&​o=|FS20]] ​ |  540-552 nm  |  575-640 nm  |
 +|  4  |  Far Red  |  [[http://​www.semrock.com/​SetDetails.aspx?​id=2983|Cy5-4040C-000]] ​ |  608-648 nm  |  672-712 nm  |
 +|  5  |  A  |  none  |  none  |  none  |
 +
 +**Upon request:**
 +
 +^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Emission ​ ^
 +|  2  |  Green LP  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488009-9901-000&​o=|FS09]] ​ |  450-490 nm  |  > 515 nm  |
 +
 +==== Objectives ====
 +^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ^ (color) ​ 10 μm =  ^  Reference ​ ^
 +|  10x  |  EC Plan-Neofluar ​ |  Air  |  0.30  |  5.2  |  1.00  |  10 pixels ​ |  23.3 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420340-9901-000/​Objective-EC-Plan-Neofluar-10x-0.30-M27|420340-9901-000]] ​ |
 +|  20x  |  EC Plan-Neofluar ​ |  Air  |  0.50  |  2  |  0.48  |  21 pixels ​ |  46.7 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420350-9900-000/​Objective-EC-Plan-Neofluar-20x-0.50-M27|420350-9900-000]] ​ |
 +|  40x  |  EC Plan-NeoFluar ​ |  Air  |  0.75  |  0.71  |  0.24  |  41 pixels ​ |  93.7 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440350-9903-000/​Objective-EC-Plan-Neofluar-40x-0.75|440350-9903-000]] ​ |
 +|  63x  |  Plan-Apochromat DIC  |  Oil  |  1.40  |  0.19  |  0.15  |  65 pixels ​ |  -  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420782-9900-000/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-000]] ​ |
 +
 +
 +**Upon request:**
 +^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ^  Reference ​ ^
 +|  1.25x  |  EC Epiplan-Neofluar ​ |  Air  |  0.035  |  4  |  7.58  |  1.3 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​422310-9900-000/​Objective-EC-Epiplan-Neofluar-1.25x-0.03-M27|422310-9900-000]] ​ |
 +|  5x  |  EC Plan-NeoFluar ​ |  Air  |  0.16  |  18.5  |  2.00  |  5 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420330-9901-000/​Objective-EC-Plan-Neofluar-5x-0.16-M27|420330-9901-000]] ​ |
 +|  20x  |  EC Plan-Neofluar Ph 2  |  Air  |  0.50  |  2  |  0.48  |  21 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440341-9904-000/​Objective-EC-Plan-Neofluar-20x-0.5-Ph2|440341-9904-000]] ​ |
 +|  40x  |  Plan-Neofluar Ph3  |  Oil  |  1.30  |  0.20  |  0.24  |  41 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440451-9903-000/​Objective-EC-Plan-Neofluar-40x-1.30-Oil-Ph3|440451-9903-000]] ​ |
 +|  63x  |  Plan-Apochromat Ph3  |  Oil  |  1.4  |  0.19  |  0.15  |  65 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420781-9910-000/​Objective-Plan-Apochromat-63-1.4-Oil-Ph3-M27|420781-9910-000]] ​ |
 +
 +*** pixel sizes for binning = 1**
 +
 +==== Cameras ====
 +^  Model  ^  Type  ^  Frame Size  ^  Pixel Size (µm)  ^
 +|  [[https://​labs.pbrc.edu/​cellbiology/​documents/​CoolSNAPHQ.pdf|Photometrics Coolsnap HQ]]  |  CCD  |  1392 x 1040  |  6.45 x 6.45  |
 +|  [[https://​www.leica-microsystems.com/​products/​microscope-cameras/​p/​leica-dfc450-c/​|Leica DFC450]] ​ |  color CCD  |  2560 × 1920  |  3.4 x 3.4  |
 +
 +==== Stage ====
 +For automated acquisition of 96 well plates use:
 +X = -9014 μm
 +Y = -8995 μm
 +
 +===== System Turn On Procedures =====
 +  * Turn on the fluorescent light power source
 +{{halide_710.jpg?​80|}}
 +  * Turn on the Prior stage controller ​
 +{{ax_prior_on.jpg?​100|}}
 +  * Turn on the microscope
 +{{ax_mic_on.jpg?​100|}}
 +  * Turn on the CCD camera
 +{{ax_cam_on.jpg?​100|}}
 +  * Turn on the computer
 +  * Log in to Windows (Bioimaging User)
 +  * Start the Metamorph software
 +  * If the software doesn'​t detect the camera, power cycle the camera and try again
 +===== Microscope Turn Off procedures =====
 +  * Turn off the computer.
 +  * Turn off the camera.
 +  * If you used any __immersion oil in the objectives, clean them up__.
 +  * Turn off the microscope stage controller.
 +  * Turn off the microscope.
 +  * If there'​s __another user__ for this microscope in the __next hour__ leave the mercury __lamp power source on, else turn it off__. ​
 +  * Be extra careful in weekends and at the end of the day to make sure that the mercury lamp is not going to be turned on for an excessive time. 
 +
 +----
 +[[resources|Back to the Resources page]]